LOCATIONS:
755 Prairie Industrial Pkwy
Mulberry, Florida 33860
Ph: 863-425-4884
Toll Free: 800-276-2187
Fax: 863-425-2854
4117 Bandy Boulevard
Ft. Pierce, FL 34981
Ph: 772-464-4884
Toll Free 877-HWCLARK
Fax: 772-464-5566
|
|
|
62-713-Soil Thermal Treatment Facilities
Testing and Sampling Requirements
- Pre-Acceptance Testing Criteria-Two types
- For sites which have an approved site assessment report according to the requirements of Chapter 62-770 F.A.C., existing data from the site assessment may be used, if documented on form 62-713.900 (3) in lieu of separate pretreatment analysis including Arsenic, Cadmium, Chromium, or Lead.
- Thermal Treatment Testing
| l)Preburn -- Virgin | Test Method | >= Must Run TCLP |
| A) Volatile Organic Halocarbons | 8260B inpart, 8021B inpart |
|
| B) TRPH | FL-PRO |
|
| C) Metals-Arsenic | 6010B, 7060A, 7061A, 6020 | 100ppm |
| Cadmium | 6010B, 7180, 7131A, 6020 | 20ppm |
| Chromium | 6010B, 7190, 7191, 6020 | 100ppm |
| Lead | 6010B, 7420, 7421, 6020 | 100ppm |
| ll) Preburn -- Non-Virgin |
|
|
| A) Volatile Organic Halocarbons | 8260B inpart, 8021B inpart |
|
| B) TRPH | FL-PRO |
|
| C) Metals-Arsenic | 6010B, 7060A, 7061A, 6020 | 100ppm |
| Cadmium | 6010B, 7130, 7131A, 6020 | 20ppm |
| Chromium | 6010B, 7190, 7191, 6020 | 100ppm |
| Lead | 6010B, 7420, 7421, 6020 | 100ppm |
| D) PCB | 8082, 8270 inpart |
|
| E) TOX | 9056, 9253 |
|
| lll) Preburn -- Non-Petroleum |
|
|
| A) Volatile Organic Compounds | 8260B, 8021B |
|
| B) Semi-Volatile Organic Compounds | 8270C |
|
| C) Metals-Arsenic | 6010B, 7060A, 7061A, 6020 | 100ppm |
| Barium | 6010B, 7080A, 7081, 6020 | 2000ppm |
| Cadmium | 6010B, 7130, 7131A, 6020 | 20ppm |
| Chromium | 6010B, 7190, 7191, 6020 | 100ppm |
| Lead | 6010B, 7420, 7421, 6020 | 100ppm |
| Mercury | 7471A, 7472 | 4ppm |
| Selenium | 6010B, 7740, 7741A, 6020, 7742 | 20ppm |
| Silver | 6010B, 7760A, 7761, 6020 | 100ppm |
| D) TRPH | FL-Pro |
|
| E) Pesticides | 8081A |
|
- Sampling-Number of samples required/site tonnage
TABLE A
| Amount of Soil by Weight, tons | Number of discrete samples required for Volatile Organics |
| < 140 | 1 |
| 140 to < 700 | 3 |
| 700 to < 1400 | 5 |
| For each additional 700 tons | 1 |
Overview | Profile Document | Testing Requirements Clean Fill | Permits | Photos | New Plant
|